USBee AX Test Pod - Oscilloscope, Logic Analyzer, Signal Generator

SolutionsProductsBuyDownloadsSupportCompanyServices

USBee ZX Pod 
USBee DX Pod 
USBee AX Pod 
Data Extractors 
Basic Stamp LA 
USBee Comparison 
USBee EX Board 
USBee EX 2.0 

 

Streaming Data Extractors for the USBee AX-Pro
        Bus Analyzers / Monitors for Parallel, Serial, Async, I2C, SPI, USB, CAN, I2S, SMBus, 1-Wire

Capture the streaming real-time data flowing in your embedded design easily with the USBee AX-Pro Data Extractors.

The Data Extractors will collect the raw data from Parallel, Serial, I2C, I2S, Async, USB Full and Low Speed, SMBus, 1-Wire or CAN busses and store the data to disk or pass it to your own processing application in real-time.  

The USBee AX Streaming Data Extractors are optional software modules for use with the USBee AX-Pro Test Pod (required) which must be purchased separately.
 

Data Extractor Features

  • Captures continuous real-time bus data
  • Stores data to disk or process it in real-time
  • Runs indefinitely
  • Captures entire test sequences
  • Monitors embedded system data flows during normal operation
  • Processes or stores Megabytes, Gigabytes or Terabytes of data
  • Special Viewer to view and search through the extracted data files quickly
  • Lets you write your own software to further process the extracted data using the Extractor API libraries. 

Extractor Modules Available

Data Extractor Bundle (details...)

Parallel Bus Data Extractor (details...)

Serial Bus Data Extractor (details...)

I2C Bus Data Extractor (details...)

SPI Bus Data Extractor (details...)

High Speed ASYNC Bus Data Extractor (details...)

Low/Full Speed USB Bus Data Extractor (details...)

CAN Bus Data Extractor (details...)

I2S Bus Data Extractor (details...)

SMBus Data Extractor (details...)

1-Wire Bus Data Extractor (details...)

Data Extractor Bundle

The Data Extractor Bundle combines all USBee AX-Pro Data Extractor modules in a single package at a fraction of the cost of the individual extractors.

Includes Parallel, Serial, I2C, SPI, Async, USB, CAN, I2S, SMBus and 1-Wire Bus Extractors for the USBee AX-Pro.

 

back to top

Price: $1995

Parallel Bus Data Extractor

The Parallel Bus Data Extractor takes the real-time streaming data from an embedded 8-bit parallel bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • 8 digital channels
  • TTL Level inputs (0-5V max)
  • Synchronous or Asynchronous Clocking
  • Sync. (external) clock 1kB/s to 16MB/s*
  • Async. (internal) clock 1MB/s to 24MB/s*
  • Input in 1, 2 or 4 byte words
  • Little or Big Endian
  • Ouput to Binary File*
  • Output to Text File (Hex, Decimal, Binary or ASCII)*
  • Output to Screen*
  • Comma, Space, or Newline Delimited files
  • Output Value Filtering
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

 

 

 

 

 

back to top

Price: $495

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

Serial Data

The Serial Bus Data Extractor takes the real-time streaming data from up to 8 serial data lines, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • Continuous Real-Time Data Streaming
  • 8 digital channels
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • Synchronous or Asynchronous Clocking
  • Synchronous (external) clock 0 to 16MB/s*
  • Asynchronous (internal) clock 1MB/s to 24MB/s*
  • Input in 1, 2 or 4 byte serial words
  • Little or Big Endian
  • Output to Binary File*
  • Output to Text File (Hex, Decimal, Binary or ASCII)*
  • Output to Screen*
  • Comma, Space, or Newline Delimited files
  • Output Value Filtering
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

 

 

 

 

back to top

Price: $495

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

I2C

The I2C Bus Data Extractor takes the real-time streaming data from the I2C bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • Monitors one I2C Bus
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • Time Stamp for each packet
  • Output to Text File*
  • Output to Screen*
  • Comma or Space Delimited files
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

Price: $495

 

 

 

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

 

back to top

SM Bus

The SM Bus Data Extractor takes the real-time streaming data from the SM bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • Monitors one SM Bus
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • Time Stamp for each packet
  • Output to Text File*
  • Output to Screen*
  • Comma or Space Delimited files
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

Price: $495

 

 

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

 

back to top

SPI

The SPI Bus Data Extractor takes the real-time streaming data from an SPI bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • Monitors one SPI Bus
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • SPI Clock speeds up to 12MHz
  • Asynchronous (internal) sampling of 1MB/s to 24MB/s*
  • Output to Binary File*
  • Output to Text File*
  • Output to Screen*
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

 

back to top

Price: $495

 

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

High Speed ASYNC

The Async Bus Data Extractor takes the real-time streaming data from up to 8 embedded asynchronous buses (UART), formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • 8 digital channels
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • Baud Rates from 1200 baud to 12 Mbaud *
  • Data Bit Settings (5, 6, 7 or 8)
  • Parity Bit Settings (Mark, Space, Odd, Even, Ignore, None)
  • Time Stamps of start of bytes or packets
  • Output to Text File (Hex, Decimal, Binary or ASCII)*
  • Output to Screen*
  • Comma, Space, or Newline Delimited files
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

 

 

 

 

 

back to top

Price: $495

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

USB

The USB Data Extractor takes the real-time streaming data from the Full or Low Speed bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • One USB Bus running at Low (1.5Mbps) or Full Speed (12Mbps) USB (not High Speed)
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • Time Stamp for each packet
  • Output to Text File*
  • Output to Screen*
  • Comma, Space, or Newline Delimited files
  • Packet filter on Device Address, and/or Endpoint
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

 

 

 

 

 

 

 

back to top

Price: $495

 

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

CAN

The CAN Bus Data Extractor takes the real-time streaming data from the CAN bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • Monitors one CAN Bus
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V) – intended to be used on the digital side of a CAN bus transceiver (such as the Microchip MCP2551)
  • 11 or 29-bit identifier supported
  • Time Stamp for each packet
  • Output to Text File*
  • Output to Screen*
  • Comma or Space Delimited files
  • Packet filter on Identifier
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

Price: $495

 

 

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

 

back to top

1-Wire

The 1-Wire Bus Data Extractor takes the real-time streaming data from a 1-Wire bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • Monitors one 1-Wire Bus
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • Asynchronous (internal) sampling from 1MB/s to 24MB/s*
  • Output to Binary File*
  • Output to Text File*
  • Output to Screen*
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

 

back to top

Price: $495

 

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

I2S

The I2S Bus Data Extractor takes the real-time streaming data from an I2S bus, formats it and allows you to save the data to disk or process it as it arrives.

Specifications

  • Continuous Real-Time Data Streaming
  • Monitors one I2S Bus
  • TTL Level inputs (0-5V max, Vih = 2.0V, Vil = 0.8V)
  • I2S Bit Clock up to 12MHz
  • Asynchronous (internal) sampling from 1MB/s to 24MB/s*
  • Output to Binary File*
  • Output to Text File*
  • Output to Screen*
  • Output File Viewer (including binary, text, search and export functions)
  • Extractor API libraries interface directly to your own software to further process the extracted data.  Any language that supports calls to DLLs is supported.

 * - output bandwidths are dependent on PC USB hardware, hard disk and/or screen throughput.

 

back to top

Price: $495

 

Above is one example of the output from this extractor. For all available output formats and settings, please download the complete Users Manual above.

PC System Requirements

The Data Extractors require the following minimum PC features:

  • USBee AX-Pro Test Pod (sold separately)
  • Windows® XP or Windows® 2000 operating system
  • Pentium or higher processor
  • One USB2.0 High Speed enabled port.  It will not run on USB 1.1 Full Speed ports.
  • 32MBytes of RAM
  • 125MBytes of Hard free disk space
  • Internet Access (for software updates and technical support)

back to top

 


Copyright(c) 2006 CWAV. All rights reserved.